CONSTANT VOLTAGE OPERATION |
Regulation |
Line regulation < 0.01% + 3mV |
Load regulation < 0.01% + 5mV ( < 10A) |
< 0.02% + 5mV ( > 10A) |
Ripple & Noise |
< 1mVrms 5Hz ~ 1MHz |
Recovery Time |
< 100µS (50% Load change, Minimum load 0.5A) |
Output Range |
0 to rating voltage continuously adjustable |
|
CONSTANT CURRENT OPERATION |
Regulation |
Line regulation < 0.2% + 3mA Load regulation < 0.2% + 3mA |
Ripple Current |
< 3mArms |
Output Range |
0 to rating amperes continuously adjustable |
|
METER |
Analog |
V-meter and I-meter each one 2.5 class Dimension 60 x 80 mm |
Digital |
3 1/2 digits 0.5" LED display Accuracy + (0.5% of rdg + 2 digits) |
|
INSULATION |
Chassis and Terminal |
20MΩ or above ( DC 500V ) |
Chassis and AC Cord |
30MΩ or above ( DC 500V ) |
|
POWER SOURCE |
AC 100V/120V/220V/240V+10%, 50/60Hz |
|
ACCESSORIES |
Instruction manual x 1, Power cord x 1 Test lead GTL-105 x 1 (<3A) or GTL-104 x 1 (<10A) |
|
DIMENSIONS |
255(W) x 145(H) x 335(D) mm |
|
|
|
|